Determine the dowel bearing strength for a 3/4-in.-diameter bolt in Cottonwood with the load applied parallel to grain.
Blog
A building with a non-structural interior wall is exposed to…
A building with a non-structural interior wall is exposed to a transverse load of w = 360 lb/ft. Assume this load was determined from the load combinations, i.e. do not apply the load combinations to it. What is the roof diaphragm unit shear? Let L = 32 ft, a = 20 ft, b = 12 ft, be = 20 ft, and bi = 7 ft.
Use the AWC Special Design Provisions for Wind and Seismic,…
Use the AWC Special Design Provisions for Wind and Seismic, 2015 Edition and ASD procedures to answer the following question.A single-story wood-frame building is exposed to a wind load of wU = 325 lb/ft. For simplicity, assume this load was determined from the load combinations, i.e. do not apply the load combinations to it, and that the building has no windows or doors. Let L = 28 ft, b = 20 ft, and the height of the walls be 8.5 ft. Ignoring the effects of gravity loads, what is the net maximum uplift force at the base of the shear walls?
Use the AWC Special Design Provisions for Wind and Seismic,…
Use the AWC Special Design Provisions for Wind and Seismic, 2015 Edition and ASD procedures to answer the following question.A building with a non-structural interior wall is exposed to a transverse load of w = 205 lb/ft. The roof is sheathed with single-layer straight lumber sheathing. Is the diaphragm satisfactory in regard to the maximum diaphragm aspect ratio? Let L = 40 ft, a = 30 ft, b = 10 ft, be = 14 ft, and bi = 5 ft.
Use the AWC Special Design Provisions for Wind and Seismic,…
Use the AWC Special Design Provisions for Wind and Seismic, 2015 Edition and ASD procedures to answer the following question.A single-story wood-frame building is exposed to a wind load of wU = 355 lb/ft. For simplicity, assume this load was determined from the load combinations, i.e. do not apply the load combinations to it, and that the building has no windows or doors. Let L = 60 ft, b = 12 ft, and the height of the walls be 8 ft. The walls are sheathed with portland cement plaster. Are the shear walls satisfactory in regard to the maximum shear wall aspect ratio?
Use the AWC Special Design Provisions for Wind and Seismic,…
Use the AWC Special Design Provisions for Wind and Seismic, 2015 Edition and ASD procedures to answer the following question.A building with a non-structural interior wall is exposed to a transverse load of w = 370 lb/ft. The roof is sheathed with double-layer diagonal lumber sheathing. Is the diaphragm satisfactory in regard to the maximum diaphragm aspect ratio? Let L = 44 ft, a = 30 ft, b = 14 ft, be = 12 ft, and bi = 4 ft.
A building with a non-structural interior wall is exposed to…
A building with a non-structural interior wall is exposed to a transverse load of w = 240 lb/ft. Assume this load was determined from the load combinations, i.e. do not apply the load combinations to it. What is the roof diaphragm unit shear? Let L = 24 ft, a = 20 ft, b = 4 ft, be = 10 ft, and bi = 3 ft.
A single-story wood-frame building with an interior wall is…
A single-story wood-frame building with an interior wall is exposed to a wind load of wU = 400 lb/ft. For simplicity, assume this load was determined from the load combinations, i.e. do not apply the load combinations to it, and that the building has no windows or doors. Let L = 24 ft, a = 8 ft, b = 10 ft, and the height of the walls be 8.5 ft. If all of the walls are sheathed in the same manner and the allowable shear load of an anchor bolt parallel to the wall is 1,800 lb, would 4 anchor bolts be sufficient for the interior wall?
A shear connection is fabricated with timber rivets and lumb…
A shear connection is fabricated with timber rivets and lumber that has a moisture content of 17 percent. The lumber remains below 10 percent while the connection is in service. What wet service factor, CM, should be used?
Use the AWC Special Design Provisions for Wind and Seismic,…
Use the AWC Special Design Provisions for Wind and Seismic, 2015 Edition and ASD procedures to answer the following question.A building with a non-structural interior wall is exposed to a transverse load of w = 345 lb/ft. The roof is sheathed with blocked wood structural panels. Is the diaphragm satisfactory in regard to the maximum diaphragm aspect ratio? Let L = 36 ft, a = 30 ft, b = 6 ft, be = 16 ft, and bi = 5 ft.