For differential pressure transmitter, what is the URL?  PT-…

For differential pressure transmitter, what is the URL?  PT-109 L side is vented to the atmosphere. Answers to 2 decimals, in ________psi, ie 21.34 no units.

Published April 17, 2025
Categorized as Uncategorized

Convert [x] kg/cm2 to ____________psi. 1.00 lb = 453.592 gr…

Convert [x] kg/cm2 to ____________psi. 1.00 lb = 453.592 gr Enter answer to 2 decimals, ie 55.23 no units

Published April 17, 2025
Categorized as Uncategorized

Diagram(6).jpg FT-115 has an output of [a] psi. What is the…

Diagram(6).jpg FT-115 has an output of [a] psi. What is the signal output of FY – 115?  The units are __________________psi.  Enter your answer to 2 decimals, no units, 21.91

Published April 17, 2025
Categorized as Uncategorized

What device converts a parameter of a Process Variable into…

What device converts a parameter of a Process Variable into a standard signal? 

Published April 17, 2025
Categorized as Uncategorized

If a bubbler tube becomes clogged, what affect will this hav…

If a bubbler tube becomes clogged, what affect will this have on the instrument pressure reading?

Published April 17, 2025
Categorized as Uncategorized

Untitled(3).jpg Process variable is at [x]% What is the sign…

Untitled(3).jpg Process variable is at [x]% What is the signal output value of LT-137? Answer in ___________mA Enter your answer to 2 decimals, no units  21.00

Published April 17, 2025
Categorized as Uncategorized

tc(1).jpg If the Process Temperature is 122℉ and the Referen…

tc(1).jpg If the Process Temperature is 122℉ and the Reference Temperature is 32℉, what is the actual output signal of TT – 140?  The units are ____________mA.  Enter your answer to 2 decimals, no units, 21.99

Published April 17, 2025
Categorized as Uncategorized

tc.jpg If the Process Temperature is 122℉ and the Reference…

tc.jpg If the Process Temperature is 122℉ and the Reference Temperature is 32℉ what is the process variable input value to TT – 140?  The units are _________mV.  Enter your answer to 2 decimals, no units, 21.00 

Published April 17, 2025
Categorized as Uncategorized

orifice plate.jpg The output is [a] mA. What is the differen…

orifice plate.jpg The output is [a] mA. What is the differential pressure across the orifice plate? The units are ___________”wc.  Enter your answer to 2 decimals, no units, 21.33

Published April 17, 2025
Categorized as Uncategorized

tc(2).jpg The TC circuit at TT – 140 is reading 10.224 mV. W…

tc(2).jpg The TC circuit at TT – 140 is reading 10.224 mV. What is the process Temperature (℉) if the Reference temperature is 32℉?  The units are ____________℉.  Enter your answer to 2 decimals, no units, 21.34

Published April 17, 2025
Categorized as Uncategorized