Atrial RAte ___________bpm Ventricular RAte ____________bpm (1 point) RHythm 1P:1QRS & P & QRS associated? Yes No (.5 point) Do the P-P and R-R “march out”? Yes No (.5 point) Sinus paced rhythm? Yes No (1 point) Intervals –Only record your measurement and assessment on the lines provided if abnormal (width in sec, height in mm, shape abnormality, if isoelectric, etc.). Circle if Normal or Not Normal, based upon criteria identified in the handout, “Steps for 12 Lead Interpretation”. P __________ Normal Not Normal (.5 point) PR __________ Normal Not Normal (.5 point) QRS __________ Normal Not Normal (.5 point) ST __________ Normal Not Normal (.5 point) T __________ Normal Not Normal (.5 point) QT __________ Normal Not Normal (.5 point) Axis (Circle) Normal RAD LAD , _______ to ________ degrees (1 point) Hypertrophy (circle any that apply and NA if there is no evidence of hypertrophy) (1 point) RAH RVH LAH LVH None (not applicable) Infarction No______ Yes _______If yes, what anatomical area(s)? ____________________(1 point) Identification______________________________________________________ (1 point)
Blog
A split-wire receptacle receiving power from a single source…
A split-wire receptacle receiving power from a single source (one breaker or one fuse) is
Although not stipulated in the NEC®, some local jurisdiction…
Although not stipulated in the NEC®, some local jurisdictions have adopted what for service conductors?
The weight supported by any single conduit shall not exceed
The weight supported by any single conduit shall not exceed
Conductors in concealed raceways, even though they may becom…
Conductors in concealed raceways, even though they may become accessible by withdrawing them, are still considered
Although not stipulated in the NEC®, some local jurisdiction…
Although not stipulated in the NEC®, some local jurisdictions have adopted what for service conductors?
The neutral point in a polyphase system is the common point…
The neutral point in a polyphase system is the common point on a
Overcurrent devices do not have to be readily accessible if
Overcurrent devices do not have to be readily accessible if
Multiconductor cord or cable used to support a box must be p…
Multiconductor cord or cable used to support a box must be protected in an approved manner so that the conductors are not subjected to
A type of wire that, together with strain insulators, is use…
A type of wire that, together with strain insulators, is used to support conductors in all spans exceeding 40 feet (12 m) in length is called a